Call 08046081667 95% Response Rate

Send Email

Fire Alarm System

MechanicalSpecificationOperating temperature : - 10°C to 60°C Humidity : 10% to 93% non-condensing Dimensions (HxWxD) : Surface: 87 x 87 x 52 mm Weight : 125 gr. 6. Fault Isolator With Base: - Fault Isolator Module shall be used on panel intelligent loop communication circuits along with other modules and sensors.GENERAL: This General Technical Specification covers the technical requirement for Microprocessor Based Analogue Addressable Type Intelligent Fire Detection and Alarm System (FDAS) for Utility building and Vashi Zonal Store Building at BRIT Vashi Complex, Mumbai. SCOPE OF WORK: 1. The FDA system shall cover design, engineering, supply, erection, installation, testing & commissioning of the FDA system. 2. The FDA system shall consist of minimum following equipment: Smoke detectors, Heat detectors, and Multi criteria detectors combination of rate of rise heat detector & photo electric smoke detector, other types of detectors as per the design criteria. 3. Two MAIN FIRE ALARM CONTROL PANEL (FACP) along with accessories to integrate with the firefighting system for automatic actuation. 4. Break glass type microprocessor based addressable manual call points with chain & hammer. 5. Hooters. 6. Transponders/ Interface Modules. 7. Response indicators where required for above false ceiling detectors & normally closed rooms. 8. Power supply equipment. 9. U.P.S system with Battery back - up for 24 hours, in case of power failure, shall be provided. 10. Siren and Accessories. 11. All types of cables (FRLS) and cabling accessories. 12. Erection materials 13. Earthing Materials & Earthing. 14. Minor civil works required for installing FDA System equipment as required. 15. GI pipes /GI conduits /PVC rigid conduits and other accessories wherever required for laying of cables. Trench work, if required, for cabling. 16. All erection accessories, consumables and miscellaneous material not indicated in specification but required for completing the job in all respects. 17. Preparation of Design and detailed engineering drawings and documentation, bill of materials with specification. 18. Testing and Training for operation and maintenance of the system, manuals, asbuilt drawings, Commissioning spares till handing over of the system 19. One year onsite comprehensive warranty.
GST Fire Alarm System
  • GST Fire Alarm System
  • GST Fire Alarm System

GST Fire Alarm System

Product Price: Rs 32,000 / PieceGet Best Price

Product Brochure

Product Details:
System ComponentsFire Alarm Control Panel
Body MaterialM S Body
Wireless Frequency868MHz
Temperature-10-+55 deg C
Ip RatingIP44
ApplicationHouse
Power SupplyDC 6V(CR123A*2)
The GST 200-2/N single loop and two loop addressable fire detection control panel is packed with features that are not usually associated with smaller and medium systems. The GST 200-2/N provides a high quality solution at exceptional value. By utilizing advanced GST Protocol, the system is compatible with the complete range of GST intelligent detectors, Sounders, Call Points, Interfaces, including gas extinguishing control. The GST 200-2/N is manufactured and certified to EN54 parts 2 and 4 and to BS5839 Part 4. The GSTDef2.1 programming facilities enables advanced and complex cause and effects to be programmed with ease, including phased and cascade evacuation scenario. The GST zonal indication and control facility allows the operator to manually intervene, with evacuation and control of each zone, including control of all plant equipment under an alarm condition.

Features and Benefits
  • Listed to LPCB standard
  • Loop capacity 235 addresses loop  and 242 loop 2
  • 8x18 Graphical LCD Display
  • 30 Zone indication including manual intervention and control
  • 3 programmable alarm output
  • Positive Alarm Signal (PAS) Pre-alarm
  • Maintenance report of dirty detector
  • Networkable with all GST Intelligent Fire Alarm panels
  • Programmable form PC by GSTDef2.1
  • History log 999-events capacity in non-volatile memory
  • Test facility
  • RS485 Repeater Output (Max. 10)
  • Built-in gas extinguishing control.
  • Advanced user friendly programming software including ‘Fuzzy Logic’
  • Optional Colour Graphics
  • Optional Fireman’s Control Panel
  • Optional Panel Printer
Get Best Quote Request Callback
Agni Fire Alarm System
  • Agni Fire Alarm System
  • Agni Fire Alarm System

Agni Fire Alarm System

Product Price: Rs 4,500 / PieceGet Best Price

Product Details:
System ComponentsFire Alarm Control Panel
BrandAgni
Usage/ApplicationFire Detection
Body MaterialM S Body
Alarm Volume90- 100 db
Voltage24 VDC (Output)
Temperature0-50 Degree C
Relative Humidity90% to 95% RH Condensing
Frequency50 Hz
Number Of Zones4
Input Voltage220 VAC
Product Description:
  • Zone wise fire, open, short LED indications.
  • External s/w for reset, Silence, Lamp test.
  • Battery Low& Common fire indications
  • Attachable with all types of fire detectors.
Get Best Quote Request Callback
Fire Alarm Systems

Fire Alarm Systems

Product Price: Rs 12,500 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Details:
MaterialMild Steel
System ComponentsFire Alarm Control Panel
BrandAGNI OTHERS
TypeConventional
Usage/ApplicationAGNI
Size10
Body MaterialCopper
ColorWhite
Model Name/Number123
Alarm Volume10
Country of OriginMade in India
Fire Alarm Systems
Fire Alarm Systems

Additional Information:

  • Item Code: 235
  • Production Capacity: 100
  • Delivery Time: 1
  • Packaging Details: Fire Alarm System
Get Best Quote Request Callback
Fire Alarm Control Panel

Fire Alarm Control Panel

Product Price: Rs 5,500 / PieceGet Best Price

Product Details:
Product TypeFire Alarm System
Operating VoltageAC
Usage/ApplicationCommercial
BrandAgni
Dimension0*0*0
Zones2
Model Name/Number001
2 Zone Control Panel
Get Best Quote Request Callback
ISO-X(A) Honeywell Fault Isolator Module

ISO-X(A) Honeywell Fault Isolator Module

Product Price: Rs 34,999 / PieceGet Best Price

Product Brochure

Product Details:
Body MaterialHoneywell
Model Name/NumberISO-X(A)
Usage/ApplicationSignal Isolation
Normal Operating Voltage15 - 32 VDC (peak)
Standby Current450 A (not isolating)
Temperature Range32 DegreeF to 120 DegreeF (0 DegreeC to 49 DegreeC)
Relative Humidity10% to 93% (non-condensing)
Weight150 gm
Dimensions4.5 x 4.5 x 0.25 inch (H x W x D)
The Notifier ISO-X(A) Fault Isolator Module is used with Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs) to protect the system against wire-to-wire short circuits on the SLC loops.

Features:
  • Powered by SLC loop directly, no external power required.
  • Base mounts on standard junction boxes (4.0"/10.16 cm square by 2.125"/5.398 cm deep).
  • Integral LED blinks to indicate normal condition. Illuminates steady when short circuit condition is detected.
  • High noise (EMF/RFI) immunity.
  • Wide viewing angle of LED.
  • SEMS screws with clamping plates for ease of wiring.
  • Opens SLC loop automatically on detection of short, preventing the short from causing failure of the entire loop.
  • Automatically resets on correction of short.
  • Supports Style 4, 6, or 7 wiring
Get Best Quote Request Callback

EXPLORE MORE CATEGORIES

Looking For "Fire Alarm System"?
Thank you Your Enquiry has been sent successfully.

Ratings & Reviews

Mapple Outright Services Private Limited

4.2/5

★★★★★★★★★★

Rated by 22 Users

  • 5★13
  • 4★3
  • 3★5
  • 2★0
  • 1★1

© Mapple Outright Services Private Limited. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.